CHEM8+ |
Sodium (Na) |
Potassium (K) |
Chloride (Cl) |
TCO2 |
Anion Gap* |
Ionized Calcium (iCa) |
Glucose (Glu) |
Urea Nitrogen (BUN)/Urea |
Creatinine (Crea) |
Hematocrit (Hct) |
Hemoglobin* (Hgb) |
*Calculated
Fast evaluation of metabolic status and renal function
95μL
Arterial or other venous whole blood sample
09P31-25
Reportable Range | Reference Range (Arterial) | Reference Range (Venous) | |
Sodium (Na) | 100-180 mmol/L (mEq/L) | 138-146 mmol/L (mEq/L) | 138-146 mmol/L (mEq/L) |
Potassium (K) | 2.0-9.0 mmol/L (mEq/L) | 3.5-4.9 mmol/L (mEq/L) | 3.5-4.9 mmol/L (mEq/L) |
Chloride (Cl) | 65-140 mmol/L (mEq/L) | 98-109 mmol/L (mEq/L) | 98-109 mmol/L (mEq/L) |
TCO2 | 5-50 mmol/L (mEq/L) | 23-27 mmol/L (mEq/L) | 24-29 mmol/L (mEq/L) |
Anion Gap* | (-10)-(+99) mmol/L (mEq/L) | 10-20 mmol/L (mEq/L) | 10-20 mmol/L (mEq/L) |
Ionized Calcium (iCa) | 0.25-2.50 mmol/L, 1.0-10.0 mg/dL | 1.12-1.32 mmol/L, 4.5-5.3 mg/dL | 1.12-1.32 mmol/L, 4.5-5.3 mg/dL |
Glucose (Glu) | 1.1-38.9 mmol/L, 20-700 mg/dL | 3.9-5.8 mmol/L, 70-105 mg/dL | 3.9-5.8 mmol/L, 70-105 mg/dL |
Urea Nitrogen (BUN)/Urea | 3-140 mg/dL, 1-50 mmol/L (Urea) | 8-26 mg/dL, 2.9-9.4 mmol/L (Urea) | 8-26 mg/dL, 2.9-9.4 mmol/L (Urea) |
Creatinine (Crea) | 0.2-20.0 mg/dL, 8-1768 μmol/L | 0.6-1.3 mg/dL, 53-115 μmol/L | 0.6-1.3 mg/dL, 53-115 μmol/L |
Hematocrit (Hct) | 15-75%PCV, 0.15-0.75 Fraction | 38-51%PCV, 0.38-0.51 Fraction | 38-51%PCV, 0.38-0.51 Fraction |
Hemoglobin* (Hgb) | 5.1-25.5 g/dL, 51-255 g/L | 12-17 g/dL, 120-170 g/L | 12-17 g/dL, 120-170 g/L |
*Calculated
With i-STAT CHEM8+, healthcare professionals can obtain chemistries, electrolytes, hematocrit and hemoglobin levels in approximately two minutes without leaving the patient's side. Incorporating i-STAT CHEM8+ early in the patient experience may help transform the delivery of care by empowering you to accelerate clinical decision-making, increase operational efficiency and reduce the total cost of care. The i-STAT CHEM8+ cartridge can be used to rapidly assess the metabolic status of patients in a variety of clinical settings including; critical care, surgery, radiology, acute and emergency care, and community based settings.
In a hospital that integrated i-STAT CHEM8+ within an Ambulatory care pathway,
i-STAT significantly improved key operational metrics such as average length of stay and reduction in overnight admission rates.
Providing lab-quality results fast when every minute counts.
Links which take you out of Abbott worldwide websites are not under the control of Abbott, and Abbott is not responsible for the contents of any such site or any further links from such site. Abbott is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement of the linked site by Abbott. The website that you have requested also may not be optimised for your screen size.
Please be aware that the website you have requested is intended for the residents of a particular country or countries, as noted on that site. As a result, the site may contain information on pharmaceuticals, medical devices and other products or uses of those products that are not approved in other countries or regions.
Please be aware that the website you have requested is intended for the residents of a particular country or countries, as noted on that site. As a result, the site may contain information on pharmaceuticals, medical devices and other products or uses of those products that are not approved in other countries or regions.
The page you are trying to access is best viewed on a desktop or laptop computer.