Emergency Medical Services

transform emergency care and community paramedicine with fast, lab-accurate testing in the field

Provide Better Care, ANywhere

The i-STAT System provides emergency medical service (EMS) professionals with lab-accurate results for a wide range of tests. Benefits include:

  • Portability: Compact handheld analyzer goes where you go—from a patient’s home to an accident scene.
  • Insight: Allows you to make more informed diagnostic and treatment decisions quickly and confidently.
  • Accuracy: Lab-accurate results for tests that matter to EMS including chemistries, electrolytes, blood gases, lactate, cardiac markers, and more.
  • Speed: Results in as little as 2 minutes*
*For most cartridges

Gain critical insights in a variety of settings

The i-STAT System benefits a wide range of pre- and post-hospital environments by bringing testing to the patient, letting health care professionals make decisions when and where they are needed.

338_x_170_3C_EMTs-test-at-scene.jpg
emergency medical care

Having critical lab results in the field can speed the start of targeted, lifesaving care at the scene for ground or air transport.

338_x_170_3C_EMT-viewing-iSTAT-results-in-office.jpg
community paramedicine

Test patients at home for post-discharge follow-up, preventive assessment or chronic disease management--helping reduce hospital readmissions.

338_x_170_3C_Dr-speaking-to-webcam.jpg
remote care and telehealth

Bring lab-quality testing to remote populations and locations, providing the diagnostic information neeeded to facilitate real-time virtual collaboration with clinicians.


 

Delivering Tests That Matter

The i-STAT System delivers results for a broad range of tests in just a few minutes, including tests that are commonly used in the EMS setting:

  • CHEM8+:  Results in 2 minutes
  • CG4+:  Results in 2 minutes
  • BNP:  Results in 10 minutes
  • cTnl: Results in 10 minutes
View Full Test Menu
450_x_240_2CT_i-STAT-cartridge-group of 4.png

Lab-Quality Results in 3 Easy Steps

Step 1
338_x_170_3C_Fill-cartridge.jpg
Fill the cartridge with 2 or 3 drops of fresh whole blood.
Step 2
338_x_170_3C_insert-cartridge.jpg
Close and insert cartridge into the i‑STAT handheld.
Step 3
338_x_170_3C_view-results.jpg
View the results in minutes on the i‑STAT handheld screen.
Intended Use for cTnl Cartridge
The i-STAT cardiac troponin I (cTnl) test is an in vitro diagnostic test for the quantitative measurement of cardiac troponin I (cTnl) in whole blood or plasma. Measurements of cardiac troponin I are used in the diagnosis and treatment of myocardial infarction and as an aid in the risk of stratification of patients with acute coronary syndromes with respect to their relative risk of mortality.

Intended Use for (CG4+) Lactate Cartridge
The test for lactate, as part of the i-STAT System, is intended for use in the in vitro quantification of lactate in arterial, venous, or capillary whole blood.The i-STAT lactate test is useful for (1) the diagnosis and treatment of lactic acidosis in conjunction with measurements of blood acid/base status, (2) monitoring tissue hypoxia and strenuous physical exertion, and (3) diagnosis of hyperlactatemia.

Intended Use for BNP
The i-STAT BNP test is an in vitro diagnostic test for the quantitative measurement of B-type natriuretic peptide (BNP) in whole blood or plasma samples using EDTA as the anticoagulant. BNP measurements can be used as an aid in the diagnosis and assessment of the severity of congestive heart failure.

You are about to exit the Abbott family of websites for a 3rd party website

Links which take you out of Abbott worldwide websites are not under the control of Abbott, and Abbott is not responsible for the contents of any such site or any further links from such site. Abbott is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement of the linked site by Abbott. The website that you have requested also may not be optimised for your screen size.

Do you wish to continue and exit this website?

Yes No

You are about to enter an Abbott country or region specific website.

Please be aware that the website you have requested is intended for the residents of a particular country or countries, as noted on that site. As a result, the site may contain information on pharmaceuticals, medical devices and other products or uses of those products that are not approved in other countries or regions.

Do you wish to continue and enter this website?

Yes No

Not optimized for your device

The page you are trying to access is best viewed on a desktop or laptop computer.

I want to view this page anyway
Contact us today